P X T = Max.Pressure (psi) X Max. Temperature (F)350,000 ( 1/32" & 1/16" ) 250,000 ( 1/8" )Temperature Limits -350F to 500+FPressure Limits @ Max. Temp = 1200 psi, 800 psi for E-140 onlyPressure Limits @ Max. Temp = 1400 psi for E-900The M and Y values for E-110,E-600 & E-900 E-140 and E-250 M Y M Y1/32"tk 3.75 7600 3.5 65001/16"tk 3.00 4500 2.70 35003/32"tk 2.50 2900 2.25 22001/8"tk 2.25 2200 2.00 1600The data set forth in this presentation is typical. The users specific application should be combined with independent study and evaluation for the materials suitability. Fluorogreen E-600, Fluorogreen E-110, Fluoroblue E-140, Fluoromaroon E-250 and Fluorowhite E-250 are registered trademarks of United Fluoro Components. All Fluorogreen Products are made in the U.S.A